NSPIRE electrical inspection

How to Properly Inspect Electrical Outlets, Switches, and Conductors Under NSPIRE Standards

Electrical systems are a critical component of any multifamily property — not just for comfort and functionality, but for safety. Under HUD’s NSPIRE (National Standards for the Physical Inspection of Real Estate) protocols, electrical outlets, switches, and conductors must meet strict standards to protect residents from shock hazards, fires, or other electrical dangers.

In this guide, we’ll break down what landlords, property managers, and inspectors need to know about NSPIRE electrical inspection rules and procedures—covering exactly how to inspect these systems and what common deficiencies to watch for.


Understanding the Scope of NSPIRE Electrical Standards

What’s included in an NSPIRE electrical inspection?

Under NSPIRE, the following electrical components are evaluated during HUD property inspections:

  • Electrical Outlets: Any installed power outlets connected to an electrical system

  • Electrical Switches: Light switches or other switches connected to the property’s power supply

  • Electrical Conductors: Wires, cables, or metal components that carry current

HUD defines these components as essential systems that must be in safe, working condition, free of hazards, and properly installed in accordance with the National Electrical Code (NEC).


NSPIRE Electrical Inspection Procedures: How to Inspect

Here’s a step-by-step overview of how to properly inspect electrical components under NSPIRE:

1. Visual Inspection of All Accessible Outlets and Switches

Walk through the unit and visually inspect every outlet and switch. Check for:

  • Cracked or broken outlet or switch covers

  • Missing outlet or switch covers

  • Exposed wires or conductors

  • Loose outlets or switches

  • Burn marks or signs of overheating

HUD expects all outlets and switches to be covered and properly secured to the wall or junction box.


2. Testing for Functionality

Test each outlet and switch to ensure functionality:

  • Outlets: Use a UL-approved outlet tester to verify proper wiring, ground, and polarity.

  • GFCI Outlets: Press the TEST button and verify the outlet trips properly, then RESET.

  • Switches: Turn each switch on and off to confirm operation of connected lighting or appliances.

Inoperable outlets or switches will be cited as deficiencies.


3. Inspecting Conductors

For conductors (wiring):

  • Look for any visible exposed wiring or improperly terminated conductors.

  • Check junction boxes — if accessible — to confirm conductors are properly enclosed and capped.

  • Verify that flexible cords are not being used as permanent wiring.

HUD inspectors will flag exposed conductors or unsafe wiring practices under NSPIRE.


Common Deficiencies and Scoring Under NSPIRE

NSPIRE categorizes electrical deficiencies by severity:

  • Life-Threatening (LT):

    • Exposed conductors carrying current

    • Missing or broken cover plates exposing live parts

    • Improperly functioning GFCI outlets in required locations (kitchens, bathrooms, exterior areas)

  • Severe:

    • Inoperable outlets or switches required for essential lighting or appliances

  • Moderate:

    • Cosmetic damage that doesn’t expose wiring but may impact usability or maintenance

  • Low:

    • Minor issues that do not directly affect electrical safety or functionality

Important: LT electrical deficiencies must be corrected within 24 hours of identification. Other deficiencies typically require correction within 30 to 60 days.


Common Mistakes That Lead to NSPIRE Electrical Deficiencies

Even seasoned landlords and property managers can overlook some of these frequent issues:

  • Forgetting to test GFCI outlets during unit inspections

  • Not replacing missing outlet or switch covers

  • Failing to notice loose outlets in walls (wiggling outlets are an indicator)

  • Overlooking hidden exposed wires in closets, basements, or garages

  • Assuming that older units are grandfathered in — under NSPIRE, current safety standards apply!


Tips for Passing Your NSPIRE Electrical Inspection

To stay compliant and avoid costly citations:

  • Add electrical testing to your annual preventive maintenance checklist

  • Train maintenance staff on NSPIRE electrical inspection procedures

  • Always perform pre-inspections before official REAC/NSPIRE inspections

  • Keep GFCI outlets updated in all required locations

  • Replace damaged or missing covers immediately

  • Ensure that licensed electricians perform any wiring work — and document it


How The Inspection Group Can Help

At The Inspection Group, we specialize in helping property owners and managers prepare for NSPIRE electrical inspections and full-property compliance. Our expert team can:

We stay up-to-date on all HUD NSPIRE protocols — so you don’t have to navigate them alone!

Electrical safety is a top priority under NSPIRE. By understanding how to properly inspect outlets, switches, and conductors—and correcting common hazards—you can protect residents, avoid life-threatening citations, and ensure inspection success.

For expert support, contact The Inspection Group today. We’ll help you implement inspection-ready practices for electrical safety and beyond.